| KTX -1 ONLY COOL |
|
10 |
13 |
15 |
17 |
19 |
25 |
31 |
| KTXH-1 ONLY HEAT |
|
|
|
|
|
|
|
|
| Refrigerant yield (1) |
W |
9800 |
13000 |
14500 |
16800 |
18900 |
25400 |
31000 |
| Absorbed power in cooling(1) |
W |
3769 |
4545 |
4949 |
6087 |
6517 |
8328 |
10000 |
| Heating Yield(1) |
W |
9600 |
12100 |
14200 |
15800 |
19000 |
24200 |
30500 |
| Absorbed power in heating(1) |
W |
3097 |
4321 |
4581 |
5745 |
6032 |
8800 |
9531 |
| Tension/phase/frequency |
V-Ph+N-Hz |
230/1/50 |
230/1/50 |
400/3+N/50 |
400/3+N/50 |
400/3+N/50 |
400/3+N/50 |
400/3+N/50 |
|
|
|
|
|
|
|
|
|
| Refrigerant |
|
|
|
R410a |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Compressors |
tipo |
Scroll |
Scroll |
Scroll |
Scroll |
Scroll |
Scroll |
Scroll |
| Refrigerant Circuits |
n° |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
|
|
|
|
|
|
|
|
| INDOOR FAN |
n° |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
tipo |
Centrifugal |
Centrifugal |
Centrifugal |
Centrifugal |
Centrifugal |
Centrifugal |
Centrifugal |
| Trasmission |
|
Direct |
Direct |
With pulley |
With pulley |
With pulley |
With pulley |
With pulley |
| Motor fans absorption |
KW |
0,4 |
0,6 |
0,75 |
0,75 |
1,1 |
1,1 |
1,5 |
| Tension/phase/frequency |
V-Ph+N-Hz |
230/1/50 |
230/1/50 |
400/3+N/50 |
400/3+N/50 |
400/3+N/50 |
400/3+N/50 |
400/3+N/50 |
| Rated air capacity (indoor unit) |
m³/h |
1930 |
2640 |
2940 |
3190 |
3860 |
4780 |
5530 |
| Available fixed pressure (2) |
Pa |
90 |
100 |
170 |
160 |
210 |
240 |
250 |
|
|
|
|
|
|
|
|
|
| OUTDOOR FANS |
|
|
|
|
|
|
|
|
| Class |
|
|
|
Helicoidal |
|
|
|
|
| Quantity |
n° |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
| Trasmission |
|
Direct |
Direct |
Direct |
Direct |
Direct |
Direct |
Direct |
| Rated air capacity |
m³/h |
5200 |
9000 |
9000 |
9000 |
9000 |
12000 |
12000 |
| Electric absorption |
KW |
0,49 |
0,49 |
0,49 |
0,49 |
0,49 |
0,9 |
0,9 |
| Tension/phase/frequency |
V-Ph+N-Hz |
230/1/50 |
230/1/50 |
230/1/50 |
230/1/50 |
230/1/50 |
230/1/50 |
230/1/50 |
|
|
|
|
|
|
|
|
|
| Dimensions |
L mm |
1150 |
1345 |
1345 |
1345 |
1345 |
1445 |
1445 |
|
P mm |
1115 |
1320 |
1320 |
1320 |
1320 |
1420 |
1420 |
|
H mm |
750 |
905 |
905 |
905 |
905 |
1320 |
1320 |
| Working weight |
Kg |
165 |
219 |
223 |
223 |
243 |
320 |
343 |
|
|
|
|
|
|
|
|
|
| (1) Accord. scheme EN 14511 fan correction included: outdoor air is 27°C bs e 50% u.r e outdoor air is 35°C bs/24°C bu
bu |
| Rated air capacity to the exchanger |
| (2) To the rated air capacity and to a fan speed max. airfilter included. |
|